Jump to content

英文维基 | 中文维基 | 日文维基 | 草榴社区

MHV connector

From Wikipedia, the free encyclopedia
MHV connector
Two coupled MHV elbows showing both plug and jack ends.
Type RF coaxial connector
Production history
Manufacturer Various
General specifications
Diameter Male:  0.385 in (0.98 cm)
(inner, bayonet)[1]
Female:  0.378 in (0.96 cm)
(outer, typical)[1]
Cable Coaxial
Passband Typically 0–300 MHZ
Electrical
Max. voltage 5000Vpk
Max. current 3A

The MHV (miniature high voltage) connector is a type of RF connector used for terminating coaxial cable.[2][3][4]

Description

[edit]

The connector looks almost identical to a typical BNC connector, but is designed to not mate with BNC jacks. It features two bayonet lugs on the female connector; mating is fully achieved with a quarter turn of the coupling nut. The dimensions of the connector are specified in the MIL-STD-348B. MHV connectors can be recognized by the slightly protruding insulation on the male plug and the slightly different insulation length in the female jack.

Use

[edit]

The MHV connector is typically rated for 1500 VRMS continuous and 5000 V peak, and 3 amperes. With an operating frequency limited to about 300 MHz their usage is restricted to low frequency applications.[2][3][4][1] It was commonly used in laboratory settings for voltages beyond the rating of BNC connectors. Other applications include:

Safety hazards

[edit]
Comparison of male and female MHV connectors (left) with BNC (right)

MHV connectors are a safety hazard because the central pin is close enough to the end to allow accidental contact with it when the connector is not plugged in,[5][6][3] and because the ground connection is broken before the power connection when demating.[4]

An additional problem is that MHV connectors are easily mistaken for BNC connectors by users who are unaware of the difference, and MHV and BNC plugs and jacks can be made to mate by brute force.[3] This causes safety hazards, since a user can mate a low voltage cable to a high voltage jack.

SHV connectors are designed to prevent these hazards, and cannot be mated to BNC connectors.[3]

References

[edit]
  1. ^ a b c "Huber & Suhner RF Coaxial Connectors general catalogue".
  2. ^ a b c d e f "Amphenol MHV Connectors".
  3. ^ a b c d e "High voltage connector types".
  4. ^ a b c "Halberd Bastion MHV connectors".
  5. ^ "ALS Beamline Electrical Safety Guidelines". Archived from the original on 16 September 2008. Retrieved 5 October 2020.
  6. ^ Garland, Jim (12 Sep 2010). "Amps HV wires, back-to-back diodes, and B- wiring". Amps (Mailing list).
[edit]