A laminar flow cabinet or tissue culture hood is a partially enclosed bench work surface designed to prevent contamination of biological samples, semiconductor wafer, or any particle-sensitive materials. Air is drawn through a HEPA filter and blown in a very smooth laminar flow in a narrow vertical curtain, separating the interior of the cabinet from the environment around it. The cabinet is usually made of stainless steel with no gaps or joints where spores might collect.[1]

Despite their similar appearance, a laminar flow cabinet should not to be confused with a fume hood. A laminar flow cabinet blows unfiltered exhaust air towards the worker and is not safe for work with pathogenic agents,[2]: 13 [3] while a fume hood maintains negative pressure with constant exhaust to protect the user, but does not protect the work materials from contamination by the surrounding environment.

A biosafety cabinet is also easily-confused with a laminar flow cabinet, but like the fume hood is primarily designed to protect the worker rather than the biological samples. This is achieved by drawing surrounding air in and exhausting it through a HEPA filter to remove potentially hazardous microorganisms.

Laminar flow cabinets exist in both horizontal and vertical configurations, and there are many different types of cabinets with a variety of airflow patterns and acceptable uses. Cabinets may have a UV-C germicidal lamp to sterilize the interior and contents before use to prevent contamination of the experiment. Germicidal lamps are usually kept on for fifteen minutes to sterilize the interior before the cabinet is used. The light must be switched off when the cabinet is being used, to limit exposure to skin and eyes as stray ultraviolet light emissions can cause cancer and cataracts.[4]

See also

[edit]

References

[edit]
  1. ^ "Types of Laminar Flow Cabinets – Uses and Benefits – Information Guide". www.laminarflows.co.uk. Retrieved 19 April 2018.
  2. ^ U.S. Centers for Disease Control and Prevention; U.S. National Institutes of Health (2000). Primary Containment for Biohazards: Selection, Installation and Use of Biological Safety Cabinets (PDF). U.S. Centers for Disease Control and Prevention.
  3. ^ University of Pennsylvania (November 6, 2009). "Clean Benches vs. Biosafety Cabinets". Archived from the original on June 11, 2010. Retrieved April 24, 2010.
  4. ^ "Workplace exposure limits for ultra-violet radiation | Occupational Safety and Health Administration".
[edit]
  1. NSF/ANSI Standard 49